Professional Gas Chromatography Sample Preparation Equipment
The AutoHSS automatic headspace solid phase microextraction sampler adopts a proprietary structural design. Samples are transferred in a closed system without external interference, ensuring excellent reproducibility and superior performance for low-boiling-point components. Additionally, this instrument features headspace sampling functionality and can freely switch between headspace and solid phase microextraction modes, or be programmed for sequential runs.
| Sample Capacity | 40 sample positions |
| Injection Mode | Headspace (HS) / Solid Phase Microextraction (SPME) |
| Vial Volume | 20ml |
| Temperature Range | Ambient~180℃ |
| Control System | Touchscreen operation, method storage |
This multi-function sampler integrates headspace, thermal desorption, purge & trap, dynamic headspace, solid phase microextraction and other GC sample preparation functions, sharing a single GC input port. Functions can be switched via software for convenient operation and time-saving. It is suitable for detecting extremely low levels of volatile organic compounds (VOCs) and some semi-volatile organic compounds (sVOCs) in complex matrix samples, with high sensitivity and excellent sample fidelity.
| Sample Capacity | 40-position headspace + 50-position thermal desorption |
| Detection Limit | Vinyl chloride in water 0.05μg/L |
| Functions | Headspace, thermal desorption, purge & trap, dynamic headspace, SPME |
The AutoHS 128A automatic headspace sampler features industry-leading dual-channel sample extraction needle and static-dynamic compensation extraction technology, achieving ultra-high sensitivity. The virtually zero dead-volume tubing design eliminates carryover issues after high-concentration headspace samples. Equipped with 128 sample positions and 15 heating positions, it supports gas replacement, constant mode, time progressive and multiple headspace extraction modes.
| Sample Capacity | 128 sample positions |
| Heating Positions | 15 positions |
| Vial Volume | 20ml |
| Reproducibility | RSD ≤ 1.5% |
| Detection Capability | 1ppb benzene in water |
AutoHS 128B is an economical headspace sampler with 128 sample positions and 15 heating positions, operating in constant mode. Static-dynamic compensation injection, intelligent touchscreen interface, RSD≤1.5%, capable of detecting 1ppb benzene in water. Large capacity design suitable for high-throughput analytical laboratories, capable of unattended overnight operation.
| Sample Capacity | 128 sample positions |
| Heating Positions | 15 positions |
| Vial Volume | 20ml |
| Injection Method | Static-dynamic compensation |
| Reproducibility | RSD ≤ 1.5% |
| Detection Capability | 1ppb benzene in water |
AutoHS 40A features 40 sample positions and 15 heating positions, supporting gas replacement, constant mode, progressive mode and multiple headspace extraction (MHE). Static-dynamic compensation injection, intelligent touchscreen operation, stores 10 methods. Supports iOS remote control, RSD≤1.5%, capable of detecting 1ppb benzene in water.
| Sample Capacity | 40 sample positions |
| Heating Positions | 15 positions |
| Vial Volume | 20ml |
| Injection Method | Static-dynamic compensation |
| Reproducibility | RSD ≤ 1.5% |
| Detection Capability | 1ppb benzene in water |
AutoHS 40B is an economical headspace sampler with 40 sample positions and 15 heating positions, operating in constant mode. Static-dynamic compensation injection, intelligent touchscreen interface, RSD≤1.5%, capable of detecting 1ppb benzene in water. Suitable for routine headspace analysis applications.
| Sample Capacity | 40 sample positions |
| Heating Positions | 15 positions |
| Vial Volume | 20ml |
| Injection Method | Static-dynamic compensation |
| Operation Mode | Constant mode |
| Reproducibility | RSD ≤ 1.5% |
| Detection Capability | 1ppb benzene in water |
This instrument adopts proprietary ultra-low temperature semiconductor cooling technology with a cold trap minimum temperature of -60℃, providing excellent enrichment for C2 components, methanethiol and other low-boiling-point compounds. It uses proprietary multi-stage cold trap dehumidification technology to effectively remove H₂O, CO₂, N₂, O₂ and other inorganic gases from samples.
| Cold Trap Temperature | -60℃~400℃ (OLS PLUS) / -40℃~400℃ (OLS) |
| Cooling Method | Semiconductor electronic cooling |
| Dehumidification Technology | Multi-stage cold trap dehumidification (patented) |
| Flow Control | Online gas flow control |
| User Interface | Touchscreen, Chinese/English selectable |
| Method Storage | Stores 10 methods |
AutoHS 20 is a compact headspace sampler with 20 sample positions and 5 heating positions. Constant mode operation, static-dynamic compensation injection, suitable for laboratories with smaller sample volumes.
| Sample Capacity | 20 sample positions |
| Heating Positions | 5 positions |
| Vial Volume | 20ml |
| Injection Method | Static-dynamic compensation |
AutoHS 20E is an entry-level headspace sampler with 20 sample positions and 5 heating positions. Economical and practical, suitable for basic headspace analysis applications.
| Sample Capacity | 20 sample positions |
| Heating Positions | 5 positions |
| Vial Volume | 20ml |
| Injection Method | Static-dynamic compensation |
This instrument uses proprietary 360-degree cylindrical heating technology for primary desorption and hot gas flow instantaneous desorption technology for secondary desorption, improving desorption efficiency and speed, resulting in sharper chromatographic peaks, higher sensitivity and no residual effects. Integrated with sample spiking, standard preparation and sequential online sampling systems, it is more suitable for automatic sequential online monitoring compared to traditional thermal desorbers.
| Sample Capacity | 50-position thermal desorption |
| Primary Desorption Temp | 50-400℃ |
| Cold Trap Low Temp | -40℃~50℃ (electronic cooling) |
| Cold Trap High Temp | 50℃-400℃ |
| Transfer Line Temp | 300℃ |
| Performance Parameters | Half-peak width <3S, desorption efficiency ≥95% |
| Preparation Precision | ≤0.5% |
| System Reproducibility | %RSD≤1% |
This instrument uses proprietary 360-degree cylindrical heating technology for primary desorption and hot gas flow instantaneous desorption technology for secondary desorption, improving desorption efficiency and speed, resulting in sharper chromatographic peaks, higher sensitivity and no residual effects. Equipped with 50 sample positions, high automation design and sample overlap processing capability.
| Sample Capacity | 50 tubes |
| Primary Desorption Temp | 50-400℃ |
| Cold Trap Low Temp | -40℃~50℃ (electronic cooling) |
| Cold Trap High Temp | 50℃-400℃ |
| Transfer Line Temp | 300℃ |
| Performance Parameters | Half-peak width <3S, desorption rate >98% |
AutoTD 20 is a compact automatic thermal desorber with 20 sample positions. Uses 360-degree cylindrical heating technology, cold trap temperature range -40℃~400℃. Suitable for laboratories with smaller sample volumes.
| Sample Capacity | 20 tubes |
| Primary Desorption Temp | 50-400℃ |
| Cold Trap Temperature | -40℃~400℃ |
AutoTD 50S is an upgraded automatic thermal desorber with 50 sample positions. Features enhanced 360-degree cylindrical heating configuration for superior performance.
| Sample Capacity | 50 tubes |
| Primary Desorption Temp | 50-400℃ |
| Desorption Rate | >98% |
AutoTD D50 features a dual-channel design with 2×25 sample positions (total 50 tubes). Dual channels can operate independently or simultaneously, significantly improving analysis throughput. Uses 360-degree cylindrical heating technology, cold trap temperature range -30℃~400℃.
| Sample Capacity | 2×25 tubes (total 50 tubes) |
| Channels | Dual-channel |
| Primary Desorption Temp | 50-400℃ |
TDC 20 is used for conditioning and cleaning thermal desorption sample tubes. Equipped with 20 heating positions, can condition 20 tubes simultaneously. Temperature range 50-400℃, ensures tubes are clean and residue-free, extending service life.
| Tube Positions | 20 positions |
| Temperature Range | 50-400℃ |
| Carrier Gas | High purity nitrogen or helium |
The automatic thermal desorption tube standard addition platform is used to prepare standard sample tubes required for thermal desorption analysis, supports automatic addition of liquid and gas standards, precisely controls flow and time, and can be integrated with thermal desorption systems for one-click fully automatic operation, suitable for VOC, benzene series and other multi-standard detection, improving experimental efficiency and accuracy. Supports sequential online sampling.
| Tube Capacity | 50 positions |
| Addition Types | Liquid standard, gas standard |
| Control Method | Precise flow and time control |
| Integration | Can integrate with thermal desorption systems |
| Special Functions | Supports sequential online sampling |
This instrument adopts proprietary ultra-low temperature semiconductor cooling technology with a cold trap minimum temperature of -40℃, providing good enrichment for C3 and higher components. It uses proprietary multi-stage cold trap dehumidification technology to effectively remove H₂O, CO₂, N₂, O₂ and other inorganic gases from samples.
| Cold Trap Low Temp | -40℃ |
| Cold Trap High Temp | 50℃-400℃ |
| Cooling Method | Semiconductor cooling |
| Dehumidification Method | Multi-stage cold trap dehumidification |